RDM-3P v.1.0 - PAPER MOISTURE METER
ADDENDUM
This addendum is to be used in conjunction with the Owner’s Manual for the RDM3
Wood Moisture Meter (attached). The Owner’s Manual details the various functions of
the RDM3 meter, including the optional PC interface. This addendum contains
information specific to the paper, paper core, baled paper and corrugated applications.
We recommend the user read the Owner’s Manual and addendum completely, before
using the RDM3-P.
Changes to the RDM-3 Wood Moisture Meter that are reflected in the RDM3-P include:
All wood species have been deleted from the meter and replaced by 3 scales for
the paper applications. PAPER (5.3%-23%), RELATIVE (0-100) scale, and
BALED PAPER (8%-40%). NOTE: Displayed readings outside of this nominal
range should be taken as a “no reading”. They are included in statistical
calculations to provide a more complete profile of the moisture distribution.
The wood temperature compensation feature has been eliminated.
TESTING PAPER, PAPER CORES, AND CORRUGATED PRODUCTS
¾ Set the meter scale for PAPER. Check that the contact pins are firmly hand
tightened.
¾ Push the contact pins into the paper product to their full penetration if possible.
¾ Press the SELECT button to read %MC when in TRIGGER mode. In CONTINUOUS
mode, press SELECT to start readings and press SELECT again to store a reading.
Since the readings are the result of an “average” calibration, if a high degree of accuracy
is required, the meter should be checked on the specific material and corrections
determined by the user.
Meter readings indicate moisture content at room temperature of 70º F - 90º F. Meter
readings will be affected by lower or higher temperatures. Lower temperatures cause
readings to be lower; higher temperatures cause readings to be higher than the actual
MC.
Page view 0
1 2 3 4 5 6 ... 30 31

Summary of Contents

Page 1

RDM-3P v.1.0 - PAPER MOISTURE METER ADDENDUM This addendum is to be used in conjunct

Page 2

Copyright  2005, Delmhorst Instrument Co. Page 7 of 28 POWERING UP THE METER: 1. Press and hold the center (SELECT) button. 2. The meter switches

Page 3

Copyright  2005, Delmhorst Instrument Co. Page 8 of 28 o Setup: This menu option selects access to the rest of the meter features: Set Date and Tim

Page 4

Copyright  2005, Delmhorst Instrument Co. Page 9 of 28 o Default species: Douglas Fir o Default Temperature : 70F o Default Job Number: 1 o

Page 5 -

Copyright  2005, Delmhorst Instrument Co. Page 10 of 28 o T° (Temperature Compensation) o JOB (current job) o ALARM (current alarm setting) o MOD

Page 6 - 1. GENERAL DESCRIPTION

Copyright  2005, Delmhorst Instrument Co. Page 11 of 28 UP and DOWN keys can be used to select one of three available options. If COMP TEMP is sele

Page 7 - 2. Operating Instructions

Copyright  2005, Delmhorst Instrument Co. Page 12 of 28 Select “JOB” and use the LEFT or RIGHT keys to change the job number to the one desired. Whe

Page 8 - Page 5 of 28

Copyright  2005, Delmhorst Instrument Co. Page 13 of 28 Once a new material/specie is selected, control returns to the Create Job screen. Click SEL

Page 9

Copyright  2005, Delmhorst Instrument Co. Page 14 of 28 APPENDING DATA TO A JOB: If the chosen job does already exist, the user does not have the op

Page 10 - 3. Meter Use

Copyright  2005, Delmhorst Instrument Co. Page 15 of 28 job and associated information. The maximum storage capability of the meter is therefore det

Page 11 - Meter functions:

Copyright  2005, Delmhorst Instrument Co. Page 16 of 28 o View Statistics: This menu option selects the meter’s statistical analysis option. Select

Page 12 - Page 9 of 28

The meter tends to read the highest moisture content that is in contact with both pins. If thick samples are not well equalized, it may be necessary

Page 13

Copyright  2005, Delmhorst Instrument Co. Page 17 of 28 o The fifth line shows the value of the highest MC reading stored in the specific job. The

Page 14 - Page 11 of 28

Copyright  2005, Delmhorst Instrument Co. Page 18 of 28 A selected job containing readings offers two other selectable options: “VIEW SET” and “DONE

Page 15

Copyright  2005, Delmhorst Instrument Co. Page 19 of 28 o Cancel: This feature returns the meter to the Storage Menu o Clear Memory: This menu o

Page 16 - Page 13 of 28

Copyright  2005, Delmhorst Instrument Co. Page 20 of 28 Requirements: The wireless communication technology employed in the meter requires line-of-s

Page 17

Copyright  2005, Delmhorst Instrument Co. Page 21 of 28 delays built in to allow the other link components to come online in any sequence. Troub

Page 18 - Page 15 of 28

Copyright  2005, Delmhorst Instrument Co. Page 22 of 28 SETUP MENU: The Setup group of features allows access to the configurable parameters of

Page 19

Copyright  2005, Delmhorst Instrument Co. Page 23 of 28 decremented using the LEFT key. The DAY parameter moves forward through weekdays using the R

Page 20 - Page 17 of 28

Copyright  2005, Delmhorst Instrument Co. Page 24 of 28 NOTE: Except for clock settings, all other parameters will return to their default values, a

Page 21

Copyright  2005, Delmhorst Instrument Co. Page 25 of 28 CARE OF YOUR METER ¾ Store your meter in a clean, dry place. The protective carrying cas

Page 22 - Page 19 of 28

Copyright  2005, Delmhorst Instrument Co. Page 26 of 28 SERVICE FOR YOUR METER ¾ Before sending in your meter we recommend you give one of our tr

Page 23

The level of accuracy of meter readings depends on a number of factors: similarity between the material tested and samples on which the calibration w

Page 24 - Page 21 of 28

Copyright  2005, Delmhorst Instrument Co. Page 27 of 28 WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its (Mode

Page 25

Copyright  2005, Delmhorst Instrument Co. Page 28 of 28 SPECIES LIST: The following 69 species are programmed in the meter. The default species is

Page 26 - Page 23 of 28

RDM3 WOOD MOISTURE METER Owner’s Manual US version - 1.5 For RDM-3 Meters starting with Serial #11925 Delmhorst Instrument Co. Rev 8 May,

Page 27

Copyright  2005, Delmhorst Instrument Co. Page 2 of 28

Page 28 - Page 25 of 28

Copyright  2005, Delmhorst Instrument Co. Page 3 of 28 1. GENERAL DESCRIPTION Thank you for your purchase of Delmhorst Instrument Co.’s n

Page 29

Copyright  2005, Delmhorst Instrument Co. Page 4 of 28 2. Operating Instructions -User Guide- This guide provides step-by-step instructions on po

Page 30 - WARRANTY

Copyright  2005, Delmhorst Instrument Co. Page 5 of 28 are important, DO NOT store additional readings. Turn the meter back on and perform a PC down

Page 31 - Page 28 of 28

Copyright  2005, Delmhorst Instrument Co. Page 6 of 28 Fig. 1 Keypad Layout

Comments to this Manuals

No comments